Children’s hospital on Orlyka Street, Lviv: the seven-storey building with a facade grid and horizontal sun-shading louvres
Children’s hospital on Orlyka Street, Lviv: the main facade with the Unbroken Kids children’s medical centre sign above the entrance
Children’s hospital on Orlyka Street, Lviv: the building with a covered bay for ambulances
Children’s hospital on Orlyka Street, Lviv: the new building next to the existing hospital blocks
Children’s hospital on Orlyka Street, Lviv: the reception with a play area: book niches, children’s tables and soft toys
Children’s hospital on Orlyka Street, Lviv: the double-height lobby with an open staircase and a lounge for children and parents
About project
ASPECTS OF PROJECT FORMATION
Children’s hospital, Lviv
About project

AIMM designed the new building of the children’s hospital on Orlyka Street for an all-Ukrainian open architectural competition held by Lviv City Council in 2026. The competition was for St Nicholas Hospital at 4 Pylypa Orlyka Street. The jury picked the three best of 11 entries, and AIMM’s design won second prize. The design team was led by Anna Iskierdo.

The building extends the existing hospital campus. The site is small, sloping and tightly surrounded by other buildings, so the programme had to grow upwards. The brief asked for clean and dirty flows to be kept apart, for spaces that do not feel like a typical hospital, and for the building to keep working during air raid alerts and power cuts.

Each floor has its own function. The lower levels hold admissions and the emergency department, the outpatient unit, imaging and central sterilisation; floors 2 to 5 hold the 105-bed inpatient unit; the sixth floor holds intensive care and the seventh six operating rooms. The wards look out onto Zamarstyniv Park through full-height glazing, and external louvres protect them from overheating.

Below the building is a shelter with an intensive care room and a backup operating room. Solar panels, battery storage and a backup diesel generator keep critical systems running during power cuts, and heat recovery lowers running costs. How each solution works is explained below in “Medical design in detail”.

Competition client:
Lviv City Council
Result:
2nd prize of 11 entries
Total area:
8,951 sq m
Built-up area:
1,535 sq m
Number of storeys:
7 floors
Inpatient unit:
105 beds
Operating rooms:
6, including 2 hybrid
Intensive care:
6 beds
Children’s hospital, Lviv

Medical design in detail

How do you fit a new hospital into a steep site?

The site has a significant change in level, so one of the tasks was to provide a convenient main entrance to the building, separate entrances to the outpatient unit and the emergency department, and routes for staff and services. We proposed working with the natural terrain, landforms and planted slopes, and integrated the building into its surroundings.

How do you separate ambulances from visitors?

A hospital needs separate routes for pedestrians, cars and emergency vehicles. We designed a dedicated drive to the emergency department with controlled access and a turning area on the service yard side, so patients can be dropped off right at the entrance.

Why are the children’s wards no higher than the fifth floor?

Under clause 6.2.17 of the Ukrainian building code DBN V.2.2-10:2022, inpatient wards for children must be placed no higher than the fifth floor. So we put the main ward block on floors 2 to 5 and gave the upper levels to intensive care, surgery and building services.

How is the 105-bed inpatient unit organised?

As the brief required, we designed 45 two-bed rooms and 15 single isolation rooms, which gives 105 beds. A regular 4.2 m structural grid made it possible to plan the space efficiently with repeating modules. The treatment and diagnostic rooms above and below the wards follow the same grid.

Why are isolation rooms built with airlocks?

A children’s hospital must be able to isolate patients with infection risks. We designed separate rooms with airlocks and en-suite bathrooms that allow controlled access and the right ventilation and pressure regimes. This is a traditional solution that avoids costly airtight doors.

Why do the wards face Zamarstyniv Park?

We wanted to give children surroundings that do not feel like hospital walls only. So the whole ward frontage faces Zamarstyniv Park, with full-height glazing and a visual link to nature. This makes a stay in hospital more comfortable.

How does the sun shading work?

Full-height glazing brings in daylight but also creates a risk of overheating. We added external automated louvres with adjustable angles: in the warm season they limit direct sunlight, and in the cold season they let daylight in.

How can a hospital corridor become a space for children?

A ward corridor should not be just a way through. In the central parts of each floor we created daylit spaces where children can play, talk and rest together with their parents.

Why does the main lobby have two levels?

Because of the terrain, the main entrance and the outpatient unit sit at different levels. We joined them with a double-height lobby and an open staircase, creating a clear and visually open public space.

How does the outpatient unit work?

The outpatient unit provides consultations, diagnostics and short treatments without admission to the 24-hour inpatient unit. We designed consultation and treatment rooms, an infusion chemotherapy room and a laboratory. Each group of rooms has its own waiting area with toilets.

How are emergency patients received?

For fast admission we designed a separate covered and heated bay for two ambulances. A dedicated lift next to the department takes patients to diagnostics, intensive care and the operating suite. A backup operating room is provided in the shelter.

How were the MRI and CT requirements met?

MRI and CT rooms need special planning and engineering solutions. For MRI we provided radio-frequency shielding and magnetic field control; for CT, protective walls, special doors and viewing windows with radiation protection. There is also a preparation room, walk-through changing rooms and a separate waiting area.

How is instrument sterilisation organised?

A key task was to prevent used and sterile instruments from crossing paths. We divided the central sterile services department into dirty, clean and sterile zones with a step-by-step process from decontamination to the issue of sterile items. It is linked to the operating suite by separate “dirty” and “clean” lifts.

Why is intensive care right below the operating rooms?

The time it takes to move a patient between the operating room and intensive care is critical. We placed the six-bed intensive care unit directly below the surgical suite and linked them with a short vertical route via a dedicated lift.

How is the surgical suite organised?

One floor holds six operating rooms for different purposes: two for general surgery and trauma, two hybrid rooms and two for neurosurgery and cardiac surgery. The layout separates the flows of staff, patients, sterile supplies and used instruments, and a double-corridor system shortens routes and reduces crossings.

What is special about the hybrid operating rooms?

A hybrid operating room combines surgery with high-tech imaging. We worked out the placement of the equipment, the work zones of the medical team and a separate control room so that everyone in the operation can work together smoothly. Unlike a standard mobile C-arm, a fixed angiography system gives much higher image quality.

How are the flows inside the hospital separated?

For a hospital to work properly and quickly, the most important thing is to separate the flows of medical staff, patients and visitors, clean supplies and medical waste. Operating rooms, intensive care rooms and other areas require strict sterility. We designed separate “clean” and “dirty” lifts, a dedicated lift for emergency patients and general hospital stairs and lifts to keep these flows from crossing.

What kind of shelter does the design include?

We designed the main shelter block with an intensive care room, support and sanitary rooms, independent building services and an emergency exit, plus a backup operating room with all the rooms surgeons need to keep working without interruption.

How is the hospital made energy efficient and self-sufficient?

A hospital must keep its critical systems running even during power cuts. We provided solar panels, battery storage, a backup diesel generator, heat recovery and heating and cooling systems designed to cut operating costs.