Building height: how tall is a 5-, 9-, 16- and 25-storey building in metres
Residential building heights in metres
5, 9, 16 and 25 storeys to the same scale; dashed lines mark the conventional height thresholds in Ukrainian codes
26.5 m: lift lobbies and stricter evacuation rules47 m: a firefighting lift and a fire hose kit in every apartment73.5 m: the limit of DBN V.2.2-15, high-rise rules above
Dimensions in millimetres show the total height to the parapet. The thresholds refer to the conventional height: from the fire-engine access level to the top residential floor level.
A 9-storey residential building is about 27–30 metres tall. The calculation is simple: multiply the floor-to-floor height by the number of storeys and add 2–5 m for the plinth, the technical floor or attic and the parapet. Typical Soviet panel and brick buildings have a 2.8 m storey, Khrushchyovkas 2.7 m and modern in-situ concrete buildings 3.0–3.3 m.
In short. Approximate height of a residential building:
5 storeys: 15–19 m;
9 storeys: 27–30 m, up to 35 m in modern buildings;
16 storeys: 47–50 m, up to 58 m in modern buildings;
25 storeys: 72–75 m with a 2.8 m floor and up to 88 m with a 3.3 m floor.
Building height in metres: a table for 3 to 25 storeys
The formula is simple: number of storeys × floor-to-floor height + 2–5 m for the plinth, the technical floor or attic and the parapet. The lower end of the range is a building with a low plinth and a combined roof without a technical floor; the upper end is one with a high plinth and a technical floor or attic.
Storeys
2.8 m storey (Soviet and standard series)
3.0–3.3 m storey (modern buildings)
3
10–13 m
11–15 m
4
13–16 m
14–18 m
5
16–19 m
17–22 m
9
27–30 m
29–35 m
10
30–33 m
32–38 m
12
36–39 m
38–45 m
14
41–44 m
44–51 m
16
47–50 m
50–58 m
20
58–61 m
62–71 m
25
72–75 m
77–88 m
This is the total height: from the ground to the roof parapet. A lift machine room on part of the roof adds another 3–4 m. Fire codes determine height differently; see Height thresholds in the codes below.
Calculator
Convert storeys to metres and metres to storeys
Number of storeys
Building type
Ground floor
How many storeys in 20, 30, 40, 50, 60, 100 and 200 metres
The reverse calculation: subtract 2–5 m for the plinth and roof and divide by the floor-to-floor height. Residential storeys are 2.8–3.3 m and office storeys 3.6–4.0 m, so the same height fits fewer office storeys.
In short: 50 metres is 16–17 storeys in a typical building with a 2.8 m storey or 13–16 in a modern one with a 3.0–3.3 m storey. A height of 30 m fits about 9 storeys (7–10 depending on storey height), and 100 m fits 33–35 storeys with a 2.8 m storey or 28–32 with a 3.0–3.3 m storey.
Height
Residential building, 2.8–3.3 m floor
Office building, 3.6–4.0 m floor
20 m
4–6 storeys
3–5 storeys
30 m
7–10 storeys
6–7 storeys
40 m
10–13 storeys
8–10 storeys
50 m
13–17 storeys
11–13 storeys
60 m
16–20 storeys
13–16 storeys
100 m
28–35 storeys
23–27 storeys
200 m
59–70 storeys
48–55 storeys
A residential building above 73.5 m of conventional height is designed as a high-rise under DBN V.2.2-41, where floors are usually taller, so for 100 and 200 m these figures are only a guide.
Height of a 5-, 9-, 10-, 16- and 25-storey building
How tall is a 5-storey building?
15–19 m. A Series 1-464 Khrushchyovka (in Ukrainian) has a 2.7 m storey and a slab of only 10 cm: 5 × 2.7 = 13.5 m plus the plinth. It has no attic or technical floor and a flat combined roof, so the Khrushchyovka itself is about 15–16 m tall; 5-storey buildings with an attic or technical floor are taller, up to 19 m. In a Khrushchyovka, the floor of the 5th storey is 10.8 m above the ground floor level, and a lift becomes mandatory from 12 m (above 8 m it is only recommended, DBN V.2.2-15, cl. 7.4). So even under current codes such a building can do without a lift. In a modern 5-storey building with a 3.0 m storey the difference is already 12 m, and a lift is mandatory.
How tall is a 9-storey building?
About 27–30 m. Typical Soviet 9-storey blocks, such as the Series 90 panel buildings (in Ukrainian), have a 2.8 m storey: 2.64 m from floor to ceiling and a 16 cm slab. Nine storeys at 2.8 m give 25.2 m, and with the plinth, technical floor and parapet that gives 27–30 m. A modern 9-storey in-situ concrete building with a 3.0–3.3 m storey is 29–35 m tall. For example, Lakeside 11, designed by AIMM, has 9 storeys.
How tall is a 10-storey building in metres?
30–33 m with a 2.8 m floor and 32–38 m in modern buildings. At 10 storeys a building approaches the 26.5 m conventional height threshold, and with a high plinth or a 3.0 m floor it crosses it. The design then needs lift lobbies and stricter evacuation rules, so the 10th storey adds not just one more level but a different set of requirements.
Why are there so many 9-storey buildings?
Because 9 storeys is the tallest option that, under current codes, usually stays below 26.5 m of conventional height. With a 2.8 m storey, the floor of the 9th storey is 22.4 m above the ground floor level, or about 23–24 m above ground level including the plinth. Above that come lift lobbies, stricter rules for evacuation stairs and fire-engine access set further from the wall (9–11 m instead of 5–7 m), which make the building and the plot more expensive. A lift is mandatory from 5–6 storeys anyway, so a 9-storey building adds no new requirements there.
How tall is a 16-storey building?
47–50 m with a 2.8 m floor and 50–58 m in modern buildings. The 16-storey brick building by architect Suvorov (in Ukrainian), built in Kyiv from 1977, has a 2.8 m storey and is 53.2 m tall to the parapet of the lift machine room, which itself adds 3–4 m above the roof. M3, designed by AIMM, has up to 16 storeys.
How tall is a 25-storey building?
72–75 m with a 2.8 m storey and 77–88 m with a 3.0–3.3 m storey. The limit for residential buildings of fire resistance class I is 25 storeys (DBN V.2.2-15, Table 3), but what really matters is the 73.5 m conventional height: with a 3.3 m storey a 23-storey building may already exceed it and is then designed as a high-rise. The buildings of CREATOR CITY, designed by AIMM, have up to 24 storeys.
Floor-to-floor height under Ukrainian codes
Floor-to-floor height is the distance from the floor of one storey to the floor of the next (DBN V.2.2-15:2019, cl. 3.29; DBN stands for Ukraine’s State Building Codes). It consists of the room height from floor to ceiling plus the thickness of the slab with the floor build-up.
The code sets a minimum not for the storey height but for room height. Living rooms must be at least 2.5 m high, and at least 2.7 m in areas with an average monthly July temperature of 21 °C or above. The ceiling height of corridors, bathrooms and utility rooms inside an apartment may be reduced to 2.1 m (cl. 5.6).
So the common claim that “the minimum floor height under the codes is 2.8 m” is inaccurate: in DBN V.2.2-15 this is only a calculation assumption for the lift selection table (Annex B, Table B.1, note 2).
In practice, a Khrushchyovka has a 2.7 m storey, Series 90 has 2.8 m and modern in-situ concrete buildings 3.0–3.3 m: ceilings are higher there, and an in-situ concrete slab with floor build-up and sound insulation is thicker.
What adds height and what does not count as a storey
Plinth and crawl space. The ground floor level is usually 0.5–1.5 m above the ground.
A tall ground floor. Shops and offices in a residential building may keep the height of residential rooms, but rooms whose equipment layout requires it need at least 3 m from floor to ceiling (cl. 5.39), so the ground floor is often taller than the rest.
A technical floor or attic above the top residential floor. The height of a technical floor is set by the equipment (cl. 5.48).
Parapet and rooftop structures: lift machine rooms, roof exits. A lift machine room adds another 3–4 m.
The number of storeys includes all above-ground floors, including mansard and technical floors. A semi-basement counts if the top of its ceiling slab is at least 2 m above the average ground level. A technical floor above the top residential floor does not count (DBN V.2.2-15, Annex A, cl. A.9).
What makes up the floor-to-floor height
Left: Series 90; right: a modern in-situ concrete building; dimensions in millimetres
1 Room height from floor to ceiling: living rooms at least 2.5 m, or at least 2.7 m where the mean July temperature is 21 °C or above2 Slab together with the floor build-up: 160 mm in Series 90, about 300 mm in a modern in-situ concrete building3 Floor-to-floor height: 2,800 mm versus 3,050 mm
Height thresholds in the codes: 26.5, 47 and 73.5 m
For fire requirements, what matters is not the number of storeys but the conventional height: from the lowest access level of fire engine aerial ladders to the floor of the top storey, excluding upper technical floors (DBN V.1.1-7:2016, cl. 3.10). In a typical 9-storey building this is about 23–24 m, although it is 27–30 m to the parapet.
Threshold
Approx. storeys
What changes
More than 8 m and from 12 m between the ground and top floor levels
from 4 and from 5–6
A lift is recommended above 8 m and mandatory from 12 m (DBN V.2.2-15, cl. 7.4)
26.5 m of conventional height
10–11 in Soviet series, 9–10 in modern buildings
Lift exits through lift lobbies, stricter rules for evacuation stairs (cl. 7.9, 8.13–8.14), fire-engine access 9–11 m from the wall instead of 5–7 m (DBN B.2.2-12, cl. 15.3.1)
47 m
16 and above under cl. 7.13; 15–18 by calculation depending on the storey height
A firefighting lift with a capacity of at least 1,000 kg (cl. 7.13) and a fire hose kit in every apartment (cl. 8.27)
73.5 m
up to 25 under Table 3; with a 3.3 m storey from 23–24
The limit of DBN V.2.2-15: above 73.5 m, buildings are designed under DBN V.2.2-41 High-Rise Buildings
How the plot limits height
The maximum height on a specific plot is set by urban planning documentation and specified in the urban planning conditions and restrictions. The former limits by population (27 m for towns of up to 50,000 people and 48 m for those of over 50,000 to 100,000) were removed by Amendment 1 to DBN B.2.2-12:2019, in force since 1 January 2026.
Section 1-1 of a typical 9-storey building; levels in metres, dimensions in millimetres
1 Conventional height: from the fire-engine access level to the top residential floor level, 23,600 mm2 Total height: from the ground to the roof parapet, 30,100 mm
Right: levels and storey numbers. Left: heights of the plinth (1,200), a storey (2,800) and the technical floor (2,600 mm); the parapet adds another 1,100 mm up to +28.900.